Mobil - ulja za hidraulične sisteme
Vrhunski kvalitetna ulja za hidraulične sisteme koja u svom hemijskom sastavu nemaju cink i pružaju zaštitu od habanja. Za ova ulja karakterističan je jedinstveni sistem aditiva zahvaljujući kojima posjeduju izvanrednu termičku, oksidacionu i hidrolitičku stabilnost čak i u prisustvu vode, kao i u dodiru s fluidima za hlađenje pri obradi metala proizvedenim na bazi vode.
- Product Data Sheets (PDS)
- Sigurnosni list (MSDS)
Mobil DTE 10 Excell | 15 | 32 | 46 | 68 | 100 | 150 |
ISO Viscosity Grade | 15 | 32 | 46 | 68 | 100 | 150 |
Viscosity, ASTM D 445 | ||||||
cSt @ 40o C | 15.8 | 32.7 | 45.6 | 68.4 | 99.8 | 155.6 |
cSt @ 100o C | 4.07 | 6.63 | 8.45 | 11.17 | 13 | 17.16 |
Viscosity Index, ASTM D 2270 | 168 | 164 | 164 | 156 | 127 | 120 |
Brookfield Viscosity ASTM D 2983, cP @ -20 °C | 1090 | 1870 | 3990 | 11240 | 34500 | |
Brookfield Viscosity ASTM D 2983, cP @ -30 °C | 3360 | 7060 | 16380 | 57800 | ||
Brookfield Viscosity ASTM D 2983, cP @ -40 °C | 2620 | 14240 | 55770 | |||
Tapered Roller Bearing (CEC L-45-A-99), % Viscosity Loss | 5 | 5 | 7 | 11 | 7 | 7 |
Density 15o C, ASTM D 4052, kg/L | 0.8375 | 0.8468 | 0.8502 | 0.8626 | 0.8773 | 0.8821 |
Copper Strip Corrosion, ASTM D 130, 3 hrs @ 100o C | 1B | 1B | 1B | 1B | 1B | 1B |
FZG Gear Test, DIN 51354, Fail Stage | - | 12 | 12 | 12 | 12 | 12 |
Pour Point, oC, ASTM D 97 | -54 | -54 | -45 | -39 | -33 | -30 |
Flash Point, oC, ASTM D 92 | 182 | 250 | 232 | 240 | 258 | 256 |
Foam Sequence I, II, III, ASTM D 892 , ml | 20/0 | 20/0 | 20/0 | 20/0 | 20/0 | 20/0 |
Dielectric Strength, kV, ASTM D877 | 45 | 49 | 41 | |||
Acute Aquatic Toxicity (LC-50, OECD 203) | pass | pass | pass | pass | pass | pass |
Mobil DTE 10 Excel Series meets or exceeds the requirements of: | 15 | 32 | 46 | 68 | 100 | 150 |
DIN 51524-2: 2006-09 | X | X | X | X | X | X |
DIN 51524-3: 2006-09 | X | X | X | X | ||
ISO 11158 L- HV | X | X | X | |||
JCMAS HK | X | X | ||||
Bosch-Rexroth RE 90220-01 | X | X | X | |||
Arburg | X | |||||
Krauss-Maffei Kunststofftechnik | X | |||||
Mobil DTE 10 Excel Series has the following builder approvals: | 15 | 32 | 46 | 68 | 100 | 150 |
Denison HF-0 | X | X | X | |||
Eaton Vickers 694 (encompasses former I-286-S, M-2950-S or M-2952-S) | X | X | X | |||
Cincinnati Machine P69 | X | |||||
Frank Mohn, Framo hydraulic cargo pumping | X |